PT. Famed Calibration - Depok City
4.6/5
β
based on 8 reviews
Contact PT. Famed Calibration
Address : | Jl. Pd. Cibubur E No.11, RW.8, Cisalak Pasar, Cimanggis, Depok City, West Java 16452, Indonesia |
||||||||||||||
Phone : | π +877 | ||||||||||||||
Postal code : | 16452 | ||||||||||||||
Website : | https://www.famedcalibration.com/ | ||||||||||||||
Opening hours : |
|
||||||||||||||
Categories : |
h
|
heru partikno on Google
β β β β β Perusahaan Kalibrasi berstandar SNI , ada work shop service dan pelatihan
SNI standard calibration company, there is a work shop service and training
|
H
|
Horasima Sinaga on Google
β β β β β Berada di dalam komplek pondok cibubur... tempatnya di blok E 11. 50 meter setelah masuk pos satpam komplek belok kiri...
Located in Pondok Cibubur complex ... the place is in block E 11. 50 meters after entering the security guard post turn left ...
|
D
|
Dede Ajah on Google
β β β β β Laboratorium kalibrasi dan pengujian alat kesehatan dengan pelayanan yang mumpuni dan harga cukup terjangkau. Mampu melayani kalibrasi dan pengujian berbagai jenis alat kesehatan
Calibration laboratory and testing of medical devices with qualified services and affordable prices. Able to serve calibration and testing of various types of medical devices
|
R
|
Rismarini Yufita on Google
β β β β β PT kalibrasi dengan harga yg cukup terjangkau ,hasil pengukuran baik ,dan dilakukan oleh SDM yang sesuai pada bidang nya
PT calibration at a fairly affordable price, good measurement results, and carried out by appropriate human resources in their fields
|
B
|
Budiono Dio on Google
β β β β β Perusahaan yang bergerak bidang kesehatan, bagi tamu diharuskan menggunakan masker serta prokes diterapkan baik karyawan maupun orang lain yang berkunjung.
Companies operating in the health sector, guests are required to wear masks and the procedure is applied to both employees and other people who visit.
|
A
|
Ade Chandra on Google
β β β β β Calibration
|
T
|
Tri Sandhy Depok on Google
β β β β β Good
|
I
|
Iyank Salman on Google
β β β β β BSCs are the primary containment devices that protect the worker, product and environment from exposure to microbiological agents. BSC operation, as specified by NSF/ANSI Standard 49β2007. The purpose and acceptance level of the operational tests ensure the balance of inflow and exhaust air, the distribution of air onto the work surface, and the integrity of the cabinet and the filters. Other tests check electrical and physical features of the BSC.
A. Down flow Velocity Profile Test: This test is performed to measure the velocity of air moving through the cabinet workspace, and is to be performed on all Class II BSCs.
B. Inflow Velocity Test: This test is performed to determine the calculated or directly measured velocity through the work access opening, to verify the nominal set point average inflow velocity and to calculate the exhaust airflow volume rate.
C. Airflow Smoke Patterns Test: This test is performed to determine if: 1) the airflow along the entire perimeter of the work access opening is inward; 2) if airflow within the work area is downward with no dead spots or refluxing; 3) if ambient air passes onto or over the work surface; and 4) if there is no escape to the outside of the cabinet at the sides and top of the window. The smoke test is an indicator of airflow direction, not velocity.
D. HEPA Filter Leak Test: This test is performed to determine the integrity of supply and exhaust HEPA filters, filter housing and filter mounting frames while the cabinet is operated at the nominal set point velocities. An aerosol in the form of generated particulates of dioctylphthalate (DOP) or an accepted alternative (e.g., poly alpha olefin (PAO) is required for leak-testing HEPA filters and their seals. The aerosol is generated on the intake side of the filter and particles passing through the filter or around the seal are measured with a photometer on the discharge side. This test is suitable for ascertaining the integrity of all HEPA filters.
E. Cabinet Integrity Test (A1 Cabinets only): This pressure holding test is performed to determine if exterior surfaces of all plenums, welds, gaskets and plenum penetrations or seals are free of leaks. In the field, it need only be performed on Type A1 cabinets at the time of initial installation when the BSC is in a free-standing position (all four sides are easily accessible) in the room in which it will be used, after a cabinet has been relocated to a new location, and again after removal of access panels to plenums for repairs or a filter change.
F. Lighting Intensity Test: This test is performed to measure the light intensity on the work surface of the cabinet as an aid in minimizing cabinet operator fatigue.
G. UV Lamp Test: A few BSCs have UV lamps. When used, they must be tested periodically to ensure that their energy output is sufficient to kill microorganisms. The surface on the bulb should be cleaned with 70% ethanol prior to performing this test. Five minutes after the lamp has been turned on, the sensor of the UV meter is placed in the center of the work surface. The radiation output should not be less than 40 microwatts per square centimeter at a wavelength of 254 nanometers (nm).
Finally, accurate test results can only be assured when the testing equipment is properly maintained and calibrated. It is appropriate to request the calibration information for the test equipment being used by the certifier.
Certification of Biological Safety Cabinet (BSC) following NSF 49 standard.
|